1) CO_2 gas sensitive selectrede

CO_2气敏电极
2) gas sensing electrode

气敏电极
1.
Determination of ammonia in secondary brine for production of ion-exchange-membrane caustic soda by gas sensing electrode;
气敏电极法测定离子膜制碱工艺二次盐水中的氨
2.
The current decay of CO oxidation at Pt SPE gas sensing electrode in short time scale has been studied.
对短时间内Pt-SPE气敏电极上CO氧化电流的衰退现象的研究表明,Pt表面无CO吸附态情况下,衰退主要与电极阳极极化后Pt表面氧化程度加深有关;采用动电势扫描法可使电极对CO氧化的催化活性基本恢复,但随着电极的进一步极化,衰退仍会继续。
3) gas sensitive electrode

气敏电极
1.
Analysis method of ammonia in coking wastewater by means of gas sensitive electrode was introduced in the paper and also were analysed the linear range,responvesponse time,reused ratio and interfering substance.
研究了用气敏电极测定焦化厂废水中氨的分析方法,对测定的线性范围,响应时间、回收率、干扰物质等作了理论探讨和大量试验。
2.
Analysis method of ammonia in coking wastewater by means of gas sensitive electrode was introduced in the paper and also were analysed the linear range,response time,reused ratio and interfering substance.
研究了用气敏电极测定焦化厂废水中氨的分析方法,对测定的线性范围、响应时间、回收率、干扰物质等作了理论探讨和大量试验。
4) ammonia electrode

氨气敏电极
1.
The effects of pH,electrode response time,ammonia escape time and chaff in waster water on electrode electric potential were investigated when determining content of ammonia nitrogen in industry waste water through ammonia electrode.
研究应用氨气敏电极对工业废水中氨氮进行测定时,pH值、电极响应时间、氨逃逸时间,以及废水中干扰物对氨气敏电极的电极电位的影响。
2.
From the point of physical chemistry,the procedure and principle of using an ammonia electrode for the ammonia-nitrogen on-line process monitor are systemically discussed.
从物理化学角度讨论采用氨气敏电极的氨氮在线监测仪的监测过程及原理,得出水中离子总量、溶解性物质总量、表面活性剂类物质及pH是干扰氨氮在线监测仪监测精度和稳定性的主要因素;缓冲液中足够高的EDTA二钠盐和NaOH的浓度是此类仪表稳定监测的前提条件。
3.
Hydrogen ion selective electrode and ammonia electrode combined with flow injection analysis method were used to determine hydrogen and ammonia on-line in the hollow fiber flow injection membrane extraction of Nd(Ⅲ) and Sm(Ⅲ) with HEH/EHP.
采用氢离子电极和氨气敏电极与流动注射分析相结合的在线分析技术 ,对中空纤维膜器中氨化HEH/ EHP-煤油体系萃取钕、钐过程的氢离子及铵离子进行在线分析。
5) ammonia gas sensor

氨气敏电极
1.
The determination of ammonia-nitrogen in the tannery wastewater using ammonia gas sensor was studied in this paper.
文章研究了用氨气敏电极测定制革废水中的氨氮,其方法简单、快速、准确,十分适宜大批量、色度高的制革废水氨氮的快速测定。
2.
Standard addition method was proposed for the ammonia gas sensor determination of urease activity in the soil The errors due to the soil elimmated and the accuracy of the determination was improved The advantage of this method was simple operating, rapid and reliable.
本文研究了用氨气敏电极 -标准加入法测定土壤脲酶活性的新方法。
6) ammonia gas-sensing electrode

氨气敏电极
1.
Assay of L-Asparaginase by Ammonia Gas-Sensing Electrode;

用氨气敏电极测定L-天门冬酰胺酶的活力
2.
In order to set up a new rapid method to determine protein content in food, microwave digestion was adopted to treat wheat sample, ammonia gas-sensing electrode-direct reading concentration method was used to read determination results.
为建立一种快速测定食品中蛋白质的新型分析方法,选择小麦为样品,用微波程序压力消解技术进行处理,用氨气敏电极-浓度直读法直接读取数据,快速测定了小麦中的蛋白质。
补充资料:气敏电极
一类敏化的离子选择性电极,能对溶液中气体的分压产生响应,故常用于测定样品中容易转化成气体的离子组分。实质上,这种电极是一个完整的电化学电池,由离子选择性电极和参比电极组成,所以又称气敏探头。
1957年R.W.斯托等研制了第一支气敏电极──二氧化碳电极,十多年后,又相继出现了氨电极和其他电极。现在,常见的商品气敏电极能测定二氧化碳、氨、二氧化硫、氮氧化物、氟化氢、硫化氢、氰化氢。
按构型不同,气敏电极可分为两种:①隔膜式气敏电极,采用平板式离子选择性电极为指示电极,它和参比电极一起置于顶端有透气膜的外套管内,管中充有内电解液,离子选择性电极的敏感膜紧贴透气膜,两者之间只有极薄的液层,当电极插入试液或置于气体样品中时,待测的气体扩散通过透气膜进入薄层溶液,引起其中某一离子活度的变化,它可以通过由离子选择性电极和参比电极所组成的电池来进行测量。②气隙电?尥钙ぃ龅缂低吃诿鼙盏娜萜髂谥苯有谘飞戏剑馄逋ü掌憷┥⒔敫阶庞诶胱友≡裥缘缂舾斜砻娴哪诘缃庖罕〔阒小?
现以氨电极为例说明气敏电极的工作原理,其电化学电池为:
当氨气通过透气膜进入内电解液薄层时,使下列平衡发生移动:
由于内电解液中NH嬃离子浓度保持恒定,根据质量作用定律,氨的分压(正比于试样中的氨浓度)与氢离子活度成反比。因此,由玻璃电极测得的薄层溶液pH值的变化即可计算试样中氨或铵离子(经预处理后)的浓度。
气敏电极有较高的选择性,它不受试样中离子的直接干扰,但电极的响应速度较慢,对温度的变化也十分敏感。气敏电极的主要应用领域有水质分析、环境监测、生化检验、土壤和食物分析,还用于自动连续监测。
1957年R.W.斯托等研制了第一支气敏电极──二氧化碳电极,十多年后,又相继出现了氨电极和其他电极。现在,常见的商品气敏电极能测定二氧化碳、氨、二氧化硫、氮氧化物、氟化氢、硫化氢、氰化氢。
按构型不同,气敏电极可分为两种:①隔膜式气敏电极,采用平板式离子选择性电极为指示电极,它和参比电极一起置于顶端有透气膜的外套管内,管中充有内电解液,离子选择性电极的敏感膜紧贴透气膜,两者之间只有极薄的液层,当电极插入试液或置于气体样品中时,待测的气体扩散通过透气膜进入薄层溶液,引起其中某一离子活度的变化,它可以通过由离子选择性电极和参比电极所组成的电池来进行测量。②气隙电?尥钙ぃ龅缂低吃诿鼙盏娜萜髂谥苯有谘飞戏剑馄逋ü掌憷┥⒔敫阶庞诶胱友≡裥缘缂舾斜砻娴哪诘缃庖罕〔阒小?
现以氨电极为例说明气敏电极的工作原理,其电化学电池为:
当氨气通过透气膜进入内电解液薄层时,使下列平衡发生移动:
由于内电解液中NH嬃离子浓度保持恒定,根据质量作用定律,氨的分压(正比于试样中的氨浓度)与氢离子活度成反比。因此,由玻璃电极测得的薄层溶液pH值的变化即可计算试样中氨或铵离子(经预处理后)的浓度。
气敏电极有较高的选择性,它不受试样中离子的直接干扰,但电极的响应速度较慢,对温度的变化也十分敏感。气敏电极的主要应用领域有水质分析、环境监测、生化检验、土壤和食物分析,还用于自动连续监测。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条