说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 插入式多点风量测量装置
1)  insertion multi-point air flow meter
插入式多点风量测量装置
1.
insertion multi-point air flow meter, was introduced.
并以潍坊电厂超临界机组为例,介绍了一种新型风量测量装置——插入式多点风量测量装置的应用情况。
2)  air flow measuring apparatus with multiple nozzles
多喷嘴风量测量装置
1.
According to domestic and international literature and the authors several-year-old experiences , the problems about the designing, calculating and regulating of air flow measuring apparatus with multiple nozzles, which nowadays are widely used for air flow measurement in the laboratory, are described in detail.
根据国内外文献并结合作者数年来的实践经验,详细地叙述了当今广泛应用于实验室风量测量的多喷嘴风量测量装置的设计、风量计算和风量调节等问题。
3)  air flow rate measuring facility
风量测量装置
1.
The design,type selection,and application of air flow rate measuring system in Huaneng Qinbei Power Plant have been presented,the problems appeared in operation process of units being analysed,and retrofit of the air flow rate measuring facility be- ing carried out.
对机组运行过程中出现的问题进行了分析,并对风量测量装置进行了改造。
4)  bayonet gauge
插入式测量仪器
5)  measuring device for freezing point
凝固点测量装置
6)  wind speed measurement at multiple points
多点风速测量
补充资料:闭式单点、双点压力机
代码:00413
设备名称:闭式单点、双点压力机
型号规格:公称力≥800kN
计量单位:台
主要参数内容
国际先进国内先进国内一般国内落后评定方法及说明
(一)加工精度
    参照GB10924-89、GB10933-89、JB5200-91
1、滑块下平面对工作台上平面的平行度(mm)
30%精度储备20%精度储备达到规定值大于规定值 
0.02+0.10/100×滑块下平面的被测长度
     
2、滑块行程对工作台上平面的垂直度
30%精度储备20%精度储备达到规定值大于规定值 
0.05+0.02/100×滑块行程长度
     
(二)结构性能
     
1、离合器、制动器接通率,当滑块行程次数≤16次/分时为70%,≤25次/分时为60%,≤45次/分时为50%
大于规定值10%大于规定值达到规定值达不到规定值 
2、液压超负荷保险装置、微调装置、吨位指示器
全部具有全部具有部分具有没有 
(三)噪声dB(A)
     
1、公称力≤400kN
≤85≤87≤88>88 
2、公称力>400kN
≤87≤88≤90>90 