说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 二等铂电阻温度计
1)  Standard platinum resistance thermometer(Grade Ⅱ)
二等铂电阻温度计
2)  Grade I standard Platinum resistance thermometer
一等标准铂电阻温度计
1.
The methods for uncertainty evaluation of the calibration of Grade I standard Platinum resistance thermometer in Zinc and Tin freezing points,which includes the determination of Type A and Type B standard uncertainty and the calculation of the combined standard uncertainty and the effective degrees of freedom,are described.
介绍了一等标准铂电阻温度计的在锌凝固点及锡凝固点检定的不确定度的评定方法,包括A 类标准不确定度及B类标准不确定度的确定,标准不确定度的合成及有效自由度的计算,并按误差传播公式计算出了在各温度点的扩展不确定度及包含因子。
3)  Platinum resistance thermometer
铂电阻温度计
4)  platinum resistance thermometre
铂阻温度计
5)  high-temperature PRT standard
高温铂电阻温度计
6)  Standard platinum resistance thermometer
标准铂电阻温度计
1.
According to the JJF 1059\|1999, an uncertainty evaluation method for the calibration of secondary standard platinum resistance thermometers by using zinc freezing points and water boiling point is introduced.
按照规范 ,JJF10 59- 1999,对二等标准铂电阻温度计在锌凝固点及水沸点检定的不确定度进行了评定 ,通过建立测量数学模型确定各标准不确定度分量 ,并按不确定度传播公式给出固定点间各温度点的扩展不确定度及包含因子。
补充资料:碳电阻温度计(carbonresistancethermometer)
碳电阻温度计(carbonresistancethermometer)

碳电阻是由微小的石墨颗粒聚合而成。碳电阻的电阻值具有负的电阻温度系数,温度越低,电阻值越高,适用于液氦温区的测温。它灵敏度高、尺寸小,对环境参数(磁场、辐照、压力等)不敏感,它的电阻温度关系曲线光滑,可用较简单的公式来分度,一般可用

`\frac{1}{T}=sum_jA_j(logR)^j`

的表达式。碳电阻在测温时,应尽可能不超过90K,否则会影响复现性,需要重新校准,即在一个温度点上重新测定,然后调整其R-T关系式中的一个常数即成。碳电阻的热导较差,测温时要防止工作电流引起的自热效应,测量电流应尽可能的小,一般不超过100μA,在改变温度后要有几秒钟的等待时间。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条