1) synthetic suppressing of harmonics & flicker

谐波与闪变综合抑制
1.
To suppress harmonics and flicker more effectively by an active power compensator,the synthetic suppressing of harmonics & flicker is researched.
利用可控型有源补偿装置更有效的抑制谐波与电压闪变,提出了电网谐波与闪变综合抑制技术;设计了一机多能的电力电子装置,该装置采用三相四桥臂逆变器的拓扑结构,具有谐波抑制与无功补偿两种模式,分时复用;理论分析了功能切换判据的可行性,推导了基于FBD(Fryze-Buchholz-Dpenbrock)法的快速检测算法。
2) harmonic and flicker

谐波与闪变
1.
Traditional FBD(Fryze -Buchholz -Dpenbrock) method is introduced and improved,based on which,the optimized FBD algorithm is designed for three -phase four -wire system by adding a feedback circuit to enhance the real -time performance of detection and dynamic response of harmonic and flicker suppression device.
根据当前电网中存在的实际问题,提出对系统进行谐波与闪变综合抑制的必要性。
3) flicker mitigation

闪变抑制
4) harmonic restraint

谐波抑制
1.
The evolution forms of a multistep method for roundness error separation and their harmonic restraint analysis;
多步法圆度误差分离的演化形式及其谐波抑制分析
2.
The paper first analyzes its topology and operating principles, then discusses its harmonic restraint capability and design of control system.
分析了该滤波器的拓扑结构和工作原理,讨论了其谐波抑制能力及控制系统设计,提出了一种基于增量递推的预测模型用于补偿时滞带来的影响,采用基于多模PID的控制算法进行电流跟踪控制,提高了系统的跟踪精度,最后给出了仿真结果。
5) harmonic suppression

谐波抑制
1.
A new type device for harmonic suppression and reactive-power compensation;

一种新型的谐波抑制及无功补偿装置
2.
Analysis of harmonic suppression by series active power filters;

串联型有源电力滤波器对谐波抑制的分析
3.
Perturbation analysis of harmonic suppression and reactive power compensations parameters of copper mine's 6 kV bus
铜矿6kV母线谐波抑制与无功补偿的参数摄动分析
6) harmonic restraining

谐波抑制
1.
The article analyzes reactive power compensation and harmonic restraining in power electronic system.
对电力电子系统的无功功率与谐波抑制方法进行分析。
2.
The paper discusses the harmonic pollution problem and the applied principal of Active Power Filter (APF)in harmonic restraining It also analyzes the function of series Active Power Filter and shunt Active Power Filter in harmonic restraining.
在指出电网中的谐波污染问题及有源电力滤波器(Active Power Filter—APF)在谐波抑制中应用原理的同时,分析串联有源电力滤波器和并联有源电力滤波器对电网中谐波抑制的作用。
3.
In this paper ,the source and harm of power system harmonic and its detecting technolo gies are briefly introduced firstly,then a method that harmonic restraining that making use of APF is recommended in detail , finally corresponding electrocircu it and simulation made by matlab are given.
文章首先对电力系统谐波的来源、危害和检测做了简单的介绍,然后详细阐述了利用有源滤波器进行谐波抑制的方法,并有相应的电路和matlab仿真波形。
补充资料:电压波动和电压闪变抑制
电压波动和电压闪变抑制
suppression of voltage fluctuation and flicker
d ianyabodong he dianyashan bion yizhi电压波动和电压闪变抑制(suppression。fvoltage fluetuation and flieker)冶金工厂中的电弧炉、大电动机、大电焊机等工作时,负荷电流的大幅度增减,引起电压急剧变化,其变化速度大于每秒。.2%,此时出现电压调幅波中的最高电压与最低电玉均方根值之差,称为电压波动。电压波动和有时伴随产生的电压闪变导致用电设备运行不稳定,照明闪烁,影响正常生产、生活甚至人身健康。因此,须对电压波动和闪变进行抑制,使其控制在允许范围内。 在中国按国家标准(GB12326一90)规定,电力系统公共供电点的电压波动允许值为:10kV及以下为2.5%,35~110kV为2.0%,220kV及以上为1.6%。在冶金工厂内部(非公共供电点),按本行业的有关规定,当电弧炉和轧钢大电动机由单独变压器供电时,其用电电压波动允许值可放宽到5%以内。 在电弧炉的熔化期,冲击性无功负荷产生快速的电压波动,使照明灯光发生闪烁,引起人的视觉疲劳而使情绪烦燥,还可能导致电视荧屏监控图像不稳、精密电子仪器工作不正常等。此种人的眼睛对于灯闪的主观感觉称为闪变。对闪变的程度,以对人的眼睛最为敏感的loHz频谱的等效闪变电压值△V10的大小来衡量和评价,按国家标准(GB12326一90)规定,电力系统公共供电点的允许△V10推荐值为:照明要求较高的白炽灯负荷为0.4%,一般性照明负荷为。,6%。 其抑制措施是:(l)对于轧机主传动的冲击性负荷,设计时采用减少电网感抗,以提高供电点的短路容量;或利用自备发电厂发电机,大型同步电动机(如高炉电动鼓风机)进行跟踪补偿;或将两个以上的冲击负荷在时间上错开;或设立单独的静止型动态无功补偿器等加以解决。后者有晶闸管开关电容器式(TSC)、晶闸管控制电抗器式(TCR)、晶闸管控制高阻抗变压器式(TCT)、自饱和电抗器式(SSR)、可控饱和电抗器式(CSR)、复合式(TCR十TSC)和自激变换器式(SVG)等多种类型。(2)对于电弧炉冲击性负荷,设计时采用减少电网感抗以提高供电点的短路容量;或设置单独的静止型动态无功补偿器等加以解决。由于电弧炉在熔化期三相负荷经常不平衡,闪变剧烈,要分相进行控制。要求补偿器响应速度快(全过程的响应时间应小于1个周波)参设计通常采用TCR、SSR、TCT和TCR二TSC等几种静止型动态无功补偿器。 (张炳炎)
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条