1) over load protect

过负载保护
2) overload protection

过载保护
1.
Analysis of overload protection failure of PET melt booster pump;

涤纶熔体增压泵过载保护失效分析
2.
Applying the technology of high efficiency withdraw- filings and integration of machinery with electronics,the new adjustment and high effective negative pressure device and electromagnetic device with overload protection are developed.
应用高效抽屑技术和机电一体化技术,研制推出了新型深孔加工技术及其装置——可调式高效负压抽屑装置和电磁式过载保护装置。
3.
IC type overload protection circuit has gradually replaced thermal relay overload protection mode.
煤电钻采用热继电器进行过载保护方式已逐渐被IC型过载保护电路取代。
3) over-load protection

过载保护
1.
Based on the method of solving heat balance differential equation,a novel over-load protection criterion for electric motor is presented in the paper considering the heat accumulation of motor.
以热保护为研究对象,充分考虑了电机的热积累现象,通过求解热平衡微分方程的方法,给出了新的电动机过载保护判据。
2.
The over-load protection technology is an indispensable constituent of the low-voltage apparatus intellectualization, ensuring the electric motor and the distribution line safe operation.
过载保护技术是低压电器智能化技术的重要组成部分,是保证电动机、配电线路安全运行的重要技术。
3.
The paper proposed a design scheme of an intelligent type electronic over-load protection relay of motor based on μC/OS-II embedded operating system and LPC2292 embedded microprocessor.
文章提出了一种基于μC/OS-Ⅱ嵌入式操作系统和LPC2292嵌入式微处理器的智能型电子式电动机过载保护继电器的设计方案。
4) overload protection

过负荷保护
1.
Induction motor overload protection accounted for the negative sequence current effect;

考虑负序电流效应的异步电动机过负荷保护
2.
This paper describes the configuration,operation criterion,trip logic and lock out logic of the overload protection for DC Filter Capacitor C1 in Gaozhao high voltage direct current transmission(HVDC) system based on the software and hardware structure of SIMADYN D device.
介绍了基于西门子公司S IMADYN D装置软硬件结构的高肇直流输电系统直流滤波器C1电容器过负荷保护的配置情况、动作判据、出口逻辑、闭锁逻辑。
3.
The fault trip of AC filter overload protection in Gezhouba converter station leaded to the out of service of all HP11/13 low-pass AC filters.
根据葛洲坝换流站一次双极停运事故的现象,指出过负荷保护误动作是这次事故的主要原因。
5) negative sequence overload protection

负序过负荷保护
6) overload protection

过荷载保护
补充资料:电力系统开断电容负载过电压
电力系统开断电容负载过电压
capacitance switching-off overvoltage in electric power system
d lon4I xjtong ko}duon dlonrong fUZol gU0dlonyo电力系统开断电容负载过电压(capacitanceswitehing一off overvoltage in eleetrie powersystem)断路器开断电容负载时由于重嫌导致瞬态振荡引起的过电压。电力系统的电容负载有集中参数的电容器组(无功补偿电容器组和滤波电容器)和分布参数的空载线路。 开断电容负载产生过电压的机理如图(a)、(b)所示,在开断电容负载时断路器在电容电流i(t)自然过零时(::时刻)熄弧,此后电容上的电压将维持电源电动势。(t)的幅值Em,断路器电源侧电动势。(t)仍按正弦规律变化,经工频半周波(tz时刻),电源电动势到达一E,,断路器触头间电压达ZEm,可能发生重燃。重燃后电容上的电压Uc(t)从Em过渡至一E.时,将发生角频率。一1/丫厄云的高频振荡,同时伴随有高频电流ic(t)。当振荡电压达最大值一3E.时,高频电流第一次过零[t3],如果此时电弧熄灭,电容上的电压将维持在一3Eo.再经工频半周波,当e(t)为E二时,触头间电压达4E.,可能发生第二次重嫌,使电容上的电压从一3Em过渡至Em,振荡电压最大可达SE.。循此以往,电容上的电压按IE.、3E,、SEm、7E,…规律上升,直至断路器不重嫩为止。实际上,受断路器断口绝缘恢复强度的限制和断路器熄弧、重燃的随机性,以及泄漏或各种损耗的存在,过电压将低于上述分析的数值。武t) ┌────┐┌──┬─────┐ │}、‘、 ││少欠│ ‘l‘ │ │ ││ │ l} │ │ ││ ├─────┤ │ ││ │l‘、+‘轰│ │ │└──┴─────┘┌──┼────┘ │…‘│ └──┘ 开断电容负载过电压的发展过程 (a)等值电路;(b)波形示意 开断电容负载的过电压幅值与中性点接地方式和电源侧母线电容量有关。一般无功补偿电容器组和交流滤波器组的中性点不接地,过电压较高,母线上接有较大电容时能降低被开断电容上的过电压。 限制开断电容负载过电压的主要措施是:①提高断路器刚分时触头间的介质恢复强度,以避免重燃.这是限制开断电容负载过电压的根本措施,超高压断路器已基本上做到了开断空载线路不重燃.但35kV及以下系统开断电容器组的断路器还时有重燃发生,开断电容负载的特性还需进一步提高。②采用金属氧化物避雷器。主要用于保护电容器组,通过进雷器的能量与电容器组的容量紧密相关,随着电容器组容量的增大,要求避雷器的通流能力也要增大,避雷器参数宜通过计算分析来确定。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条