说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> PIV测试技术
1)  PIV technique
PIV测试技术
2)  PIV technology
PIV技术
1.
Determination of power-law flow field in annulus line with PIV technology;
应用PIV技术测量幂律流体在环空管道内的流场
2.
Then the equipments of the PIV system,tank used in the test and floe models are mentioned,velocity of flow in the ice free flow field is calibrated,and applications of PIV technology in measuring floe field under floe ice with different shadings and sizes are carried out.
本文先介绍PIV技术的试验原理,为它应用于冰下流场的测试提供理论依据,然后介绍PIV系统仪器设备、试验所用水槽和冰模型情况,并且对无冰流场进行流速标定,最后应用PIV技术对处于不同底纹和尺寸浮冰下流场和尾流进行测试研究。
3.
In this paper, author measured various regions of the flow field in UFHS in virtue of advanced PIV technology, analysed single-phase circulating water character parameters at a rate of flow such as the distribution of vorticity field, turbulence intensity, Reynolds stresses, and one section of the distribution of speed; measure
本文借助先进的PIV技术对上升流水力分选机各个区域的流场流态进行测量试验,分析单相循环水在上升流中的运动规律如涡量场、湍流度、雷诺应力、某一截面速度分布等参数;对颗粒在上升水流中的运动和分层规律进行试验与分析,并对颗粒相与液相速度进行比较分析;研究上升水流速对颗粒分离的作用。
3)  PIV technique
PIV技术
1.
The velocity maps and vorticity maps of the different side in 2-dimension flow field were also obtained by PIV technique,while the varing rules of streamline and vorticity were found by further analyzing the .
利用PIV技术测量长方形水槽模型中磁力搅拌器产生的搅拌流场,得到了不同断面的二维流场内的速度分布和涡量分布,通过对实验数据的分析研究,进一步得到水槽内流线和涡量的变化规律。
2.
In order to improve the flow con-ditions in the equipment, three typical kinds of flow regulating components have been studiedin this work with the PIV technique.
针对入口构件后设备主分离区流场中存在严重的一次涡流和二流涡流现象,首次在重力式油水分离设备中引入整流构件的概念,并对提出的数种典型整流构件,按其对设备主分离区流场的影响,应用PIV技术进行了系统的模拟实验优选研究。
4)  micro-PIV technique
Micro-PIV技术
5)  PIV
PIV技术
1.
Measuring particle size distribution and total number in the activation chamber of desulfurization system by PIV;
测量脱硫活化器内颗粒尺寸分布和颗粒数的PIV技术(英文)
2.
Application of the modified PIV for measurement of flow field in stirred tank;
改进PIV技术在测量搅拌槽内流场中的应用
3.
Image Processing Method of PIV Technique;
PIV技术的粒子图像处理方法
6)  micro-PIV
微PIV技术
1.
Design,fabrication and micro-PIVmeasurement on no-moving-part micro-pump;
无移动部件微泵的设计、制造及基于微PIV技术的流动测量
补充资料:测试结果可接受性的检查和最终测试结果的确定


测试结果可接受性的检查和最终测试结果的确定
check of the acceptability of test results and determination of the final test result

  C凡(3)二3.3d,时,取此3个结果的平均值作为最终侧试结果;否则取它们的中位数作为最终测试结果。。,为重复性标准差(即在重复性条件下所得侧试结果的标准差)。 在口田T 11792一1989中还对重复性和再现性条件下所得侧试结果可接受性的检查方法和最终测试结果的确定做了详细讨论和规定。(马毅林)ceshi 11叩uo kejieshCxjxing d6 iiancha he zuizhong ceshi】i闪旧de que心ing测试结果可接受性的检查和最终测试结果的确定(checkof山eac,ptability of test,ults助ddsterminationofthefi耐testresult)在商品检验中进行一次测试的情形不多见,当得到一个测试结果时,所得结果不可能直接与给定的重复性标准差作可接受性的检查。对测试结果的准确性有任何疑问时都应再进行一次测试。所以,对两个测试结果进行可接受性的检查是一般的情况。 可接受性的检查,实际上是一种统计检验。任何两个测试结果只要能通过可接受性的统计检验即可认为是一致的,均可接受。比如,在重复性条件下,所得结果之差的绝对值(下称绝对差)不超过相应的重复性限r(见重复性和再现性)的值,则认为两个结果是一致的,均可接受;如果两个侧试结果的绝对差超过r,则认为它们是不一致的,必须增加测试。 按国家标准《测试方法的精密度在重复性或再现性条件下所得测试结果可接受性的检查和最终测试结果的确定》(GBIT 1 1792一1989),在重复性条件下,如果两个测试结果的绝对差不超过r的值,可取两个侧试结果的平均值作为最终测试结果。如果两个结果的绝对差超过r的值,并且测试费用较低,须再做两次测试。当4个结果的极差(即其中的最大值与最小值之差)不超过相应的临界极差c,瓜(4)二3.6a,时,取4个结果的平均值作为最终测试结果。如果两个结果的绝对差超过r的值,并且测试费用较高时,只须再作一次测试。当3个结果的极差不超过相应的临界极差
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条