1.
Aiming at the high temperature faults encountered by a 150 MW air-cooled generator during operation,by analyzing the heat distribution mode of generator and the working principle of air cooler,the trouble was found to be caused by low heat-exchanging efficiency of the air cooler,resulting from damage of the heat-exchanger fin and blockage in the air passage.
针对1台150 MW空冷发电机运行温度高的问题,从发电机散热方式及空气冷却器的工作机理进行了分析,指出发电机运行温度高的原因是空气冷却器换热效率的降低,而换热肋片的损坏及空气通道的杂物堵塞是空气冷却器换热效率降低的主要因素;提出了防范措施,使冷却器效率得以提高,发电机运行温度下降。
3)  air-cooled turbogenerator
空冷汽轮发电机
1.
Author analyzes the feasibility of improvement for air-cooled technologie s by introducing the cooling principles of air-cooled turbogenerator.
通过对国内外空冷汽轮发电机发展状况的分析,指出了国内进一步研究空冷技术的必要性。
2.
In this paper,the main technical features and key points of the design and manuf acture of WX21Z-073LLT 135MW high capacity air-cooled turbogenerator which mad e by ABB license in Jinan Power Equipment Factory were introduced,and the studies of the problem as such involves generator stator coils making process,rotator s haping process,and shaft balance etc.
本文主要介绍了山东济南发电设备厂利用瑞士ABB技术开发研制的WX21Z-073LLT型大容量空 冷汽轮发电机主要技术特点和关键工艺,并围绕大型空冷汽轮发电机定子线圈、转子加工、 转子小轴系振动平衡等关键问题进行了研究。
4)  air inner-cooled generator
空内冷发电机
5)  air cooled turbogenerator
空冷汽轮发电机
1.
In this paper, firstly the optimum design model of stator winding transposition for air cooled turbogenerators is established according to the calculation and analysis of circumfluence and eddy losses in stator winding.
本文通过对空冷汽轮发电机定子线棒产生环流和涡流损耗机理的分析和研究,确定了空冷汽轮发电机定子绕组换位方案的优化设计模型,用该模型对不同股线数的多个换位方案进行了优化设计,以82MW空冷汽轮发电机为例,确定了其定子线棒换位应采用的最佳方案,并应用到工程实际设计中。
2.
This paper describes the technology characters of air cooled turbogenerator,and the studies of the problem as such involves turbogenerator rotor shaping process, rotor coils pressing and stator VPI etc.
并围绕空冷汽轮发电机转子加工、转子下线后压型、定子真空压力整浸等关键问题进行了研
6)  air cooling turbo-generator
空冷发电机组
1.
Vibration failure diagnosis and handling of an imported type135MW air cooling turbo-generator;
引进型135MW空冷发电机组振动故障诊断及处理
补充资料:空冷发电机的运行


空冷发电机的运行
operation of air-cooled generator

刀ledl组和!封闭:行冷l发电}封系互等一;损耗〔量范尸200£量范咬低,·些特l常在l功率!应由甲(即i进风,以免i升高L度愈;的品kongleng fodlon}一de yunxlng空冷发电机的运行(operation of air一cgenerator)空冷发电机的定子绕组、转子绍定子铁芯均采用空气冷却。冷却空气一般都采月循环系统,机内装有空气冷却器,对循环空气泛却。以前空气冷却方式只用于50 MW及以下白机。但由于空冷发电机不需要外部冷却系统和翻统,因此,具有造价低、运行可靠性高、维护简仁系列优点,再加之一些制造厂在绝缘系统和降作方面采用了一些新技术和新工艺,使其使用的毛围不断扩大,目前有的制造厂已生产和投运-MW空冷发电机,并认为在200 MW及以下的笔围内,空冷发电机可能成为发展方向之一。 由于空冷发电机的容量相对较小.电压相对因此作为带变动负荷或调峰机组使用时,会有一殊问题。 发电机作调峰机组使用,就不可避免地要经电压和功率因数变动情况下运行,发电机的输d和定子电流也需要作相应变动,允许变动的范日专门的温升试验确定. 50MW以下的空冷发电机一般都为表面冷外冷),因此进风温度对其绕组温升影响较大,翌温度高于额定值时.定子电流必须作相应的降低定子绕组过热。一般进风温度在35~55℃之间右1℃,定子电流较额定值降低1%一3%,进风接高,降低的百分数愈大。 由于空气内冷技术的应用,对机内冷却空左质提出了更高的要求,还对其湿度有要求:应超过50%;不超过50%,,除了原有的除尘方面的要乏①运行中的机内空气相对湿②为保证停机期间机内空气相对澳要求配备加热装里.