说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 高阻接地面
1)  High impedance ground plane(HIGP)
高阻接地面
2)  high-resistance grounding
高阻接地
1.
Aiming at high-resistance grounding faults,the operating characteristics of phase current differential protection and zero-sequence current differential protection are analyzed,and a conclusion is obtained that when high-resistance grounding,zero-sequence current differential protection is more sensitive than phase current differential protection.
针对高阻接地的特殊故障,仔细分析了分相电流差动保护和零序电流差动保护的动作特性,并得出结论:高阻接地时,零序差动比相电流差动更灵敏。
3)  grounding with high resistance
高阻接地
1.
Based on probability analysis,a new method of fault detection and location in distribution network grounding with high resistance is proposed in this paper.
针对配电网系统的单相高阻接地故障,提出了一种基于概率分析的故障检测与定位方法。
4)  high resistance grounding
高阻接地
1.
With comparing different methods of grounding and considering different factors, high resistance grounding was selected.
经过对各种接地方式的比较,综合考虑了各方面的因素之后,选择了高阻接地这一适合于船舶电力系统的接地方式。
2.
The design features of service power system in Huizhou Gas Turbine Power Plant are as follows:to adopt two-winding transformer for high voltage service power,the bus section for medium voltage service power is designed as one section;to adopt high resistance grounding for the neutral point of high voltage service power .
惠州燃机电厂厂用电系统的高压厂变选用双卷变压器、中压厂用母线段设计为一段、高压厂用电系统中性点采用高阻接地方式、不设高压公用母线、每台机组均设置一段交流保安电源,这种厂用电系统设计合理、操作维护方便。
3.
Taking the faults of high resistance grounding before and after the capacity expansion of Datong-Qinhuangdao Line,and starting from the introduction of current increment protection principles,this paper analyzes the problem of high resistance grounding in tractive power supply system,and probes into the significance of current increment protection.
以大秦线扩能改造前后发生的高阻接地故障为例,从介绍电流增量保护原理入手,分析了牵引供电系统高阻接地问题,探讨了电流增量保护的意义。
5)  high impedance grounding
高阻接地
1.
A new algorithm of fault allocation for high impedance grounding is presented,which is based on the math model of power line described by differential equation and uses the information of single terminal to allocate the fault of HV power transmission line.
提出了一种适用于高阻接地故障的故障测距新算法。
6)  high earth-Connection re-sistance
高接地电阻
补充资料:电力系统中性点接地变压器接地


电力系统中性点接地变压器接地
earthing transformer for neutral grounding

d旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。 这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷. 还有一种特殊接线的接地变压器和接地设备的组合,是1918年鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条