1) converter station in D.C. transmission system

直流输电系统内的换流站
2) DC transmission system

直流输电系统
1.
The necessity and evidence of forming the voltage class series are analyzed,and the economy of each voltage grade is compared to present the applicable range of HVDC transmission systems.
根据直流输电技术发展及其在我国电力系统中长期发展规划中的应用前景,提出为直流输电系统划分电压等级标准化序列的思想。
2.
The effect of the common ground electrode to the HVDC transmission system and the environment are researched by modeling the common ground electrode with two High Voltage Direct Current (HVDC) transmission systems and analyzing the voltage variation (rise or down) of the neutral bus in converter station.
为分析共用接地极后两直流系统受端换流站中性母线电位升的变化情况,进而研究共用接地极对直流系统稳态运行的影响,首先讨论了直流输电系统共用接地极的型式和共用接地极的特点,建立了两回直流系统共用接地极的数学模型,并结合云广特高压直流输电与贵广II回直流输电系统参数,研究分析不同运行方式下该两回直流输电系统共用接地极对直流系统运行影响大小,以及与独立接地极相比共用接地极不同运行方式对环境的影响大小,最后对共用接地极对环境的影响以及公用接地极对直流系统运行的影响方面的问题提出了解决措施。
3.
The static characteristics of DC transmission system in renovation project of HVDC system from Gezhouba to Nanqiao are verified by simulation.
通过仿真实验对葛洲坝-南桥直流输电改造工程的直流系统静态特性进行了校核,基于葛南直流输电系统的参数,描述了在实验室条件下校核直流输电系统静态特性的方法和原理。
3) DC power transmission system

直流输电系统
1.
This paper offered the operation reliability index of nation - wide HVDC power transmission system in 2004, and analyzed the reliability index for each HVDC power transmission system.
提供了2004年全国5个在运高压直流输电系统的运行可靠性指标,并分别进行了简要分析,为直流输电系统进一步提高运行管理水平提供了信息和依据。
2.
This paper provides the operation and reliability index of nation-wide HVDC power transmission system in 2002, analyzes the reliability index of every system briefly, and offers information and basis for further improvement of operation and management of HVDC power transmit system.
文章提供了全国在运高压直流输电系统2002年的运行可靠性指标,对各个系统的可靠性指标进行了简析,为直流输电系统进一步提高运行管理水平提供了信息和依据。
4) HVDC

直流输电系统
1.
Comparison and research on the reliability between the 12-pulse and 2x12-pulse HVDC transmission system;
高压直流输电系统单双12脉接线可靠性对比研究
2.
ANALYSIS ON INFLUENCE OF GROUND ELECTRODE CURRENT IN HVDC ON AC POWER NETWORK;

直流输电系统接地极电流对交流电网的影响分析
3.
Coordinated recovery strategy for multi-infeed HVDC systems;

多馈入直流输电系统的协调恢复策略
5) AC/DC power system

交直流输电系统
1.
Transient stability analysis of AC/DC power system based on PEBS method

基于PEBS法的交直流输电系统暂态稳定分析
2.
The model of a typical AC/DC power system is established using the PSCAD/EMTDC software, output data and curves of simulation are analyzed, and the reactive power of the AC/DC system is calculat.
为准确分析计算交直流输电系统的无功功率,采用基于任意周期电压电流的无功功率数学模型,推导了交直流输电系统的无功功率模型,阐述了交直流输电系统中无功功率的物理本质。
3.
The H_∞robust controller design of AC/DC power system is investigated in this paper.

首先对交直流输电系统提出一种五阶非仿射非线性不确定控制模型,该模型能综合反映交直流系统的动态特性。
6) HVDC system

直流输电系统
1.
Based on the application achievements of bifurcation theory to the voltage stability study for AC systems,it is proposed that the bifurcation theory can also be applied to the voltage stability study for HVDC systems.
详细论述了高压直流输电系统电压稳定性研究的现状,指出现有研究方法的缺点,并结合目前分岔理论在交流系统电压稳定性研究中的应用成果,提出将分岔理论应用于直流输电电压稳定性研究,并提出了分岔理论在应用到直流输电电压稳定性研究中的主要难点,提出了解决方法。
2.
A new way to calculate the reliability indices of HVDC system using FTA(Fault Tree Analysis) theory is given.
利用故障树分析的相关理论,根据直流输电的基本原理,从引起直流系统故障的原因入手,建立了高压直流输电系统的故障树结构,所建立的故障树结构,考虑了引起系统失效的所有事件和换流站内元件存在备用的情况,是一种有效的可靠性评估算法。
3.
Because there may exist negative interactions among HVDC small signal modulation controllers in multi-infeed HVDC systems, it is necessary to tune the parameters of the HVDC modulators coordinately.
构造了一个含有两个区域间低频振荡模式的双馈入交直流输电系统 ,并对该系统的各直流小信号调制器参数进行了协调优化整定 ,仿真结果表明 ,经过协调优化后得到的直流小信号调制器能提高整个交直流系统的阻尼性能 ,并具有良好的鲁棒
补充资料:换流站直流开关场故障
换流站直流开关场故障
faults in the DC switch yard of converter station
huonlluzhan zh一l一u ko一guonehong guzhong换流站直流开关场故阵(faults in the】X二switeh yard of eonverter station)主要指发生在换流站直流开关场范围内的故库.即从换流器高压端出口至直流线路隔离开关,低压端包括至接地极之间的所有设备或连线的故障。主要包括的设备有平波电扰器、直流滤波器、中性母线、接地极引线、直流断路器和隔离开关,以及直流场内通信滤波装t和直流电流、电压测量装置等。 直流开关场内的高压侧较多发生的是设备支柱绝缘子对地闪络故障,这将引起直流电流瞬时急剧增大,是换流站较严重的故障。当发生故障时,相应的保护动作使直流系统停运。 直流开关场内的低压侧,通常发生的是中性母线或接地极引线对地短路或断线故障。如果发生对地短路故障,直流电流将流过站内接地网,造成站内接地网电位升高,使换流变压器中性接地点流人直流电流,引起直流偏磁增大而产生饱和。如果发生开路故障,则直流电流将中断,并使中性母线设备承受很大的过电压应力。 直流开关场中的设备故障主要指直流滤波器、平波电抗器的故障.直流滤波器可能发生内部短路故障、元部件的过负荷造成元件过热,或者由于支路内电容器元件的损坏数量达到一定程度后而导致电容器组件内的其它电容器元件雪崩式损坏。油浸式平波电抗器故障与变压器故障基本相同。空气绝缘的平波电抗器通常会由于绝缘设计强度或制造工艺问题而引起内部绕组局部发热而损坏。这些故障直接威胁直流系统的设备安全,都将由控制或保护动作而使直流系统停运。直流开关场的开关设备中,比较特殊的是金属回路转换断路器(MRTB)和金属回路转换开关(MRTS)。直流系统在从大地回路运行方式转换为金属回路运行方式时,MRTB需要切断的电流值约达运行直流电流的80%~90%。如果转换不成功,则MRTB必须要经受数百毫秒间隔的拉断电弧的时间,然后才能得到保护发出的重合命令,以避免MRTB的损坏。当系统中发生某些特殊不正常工况时,如大地回路运行而一端接地极损坏或接地极引线断开,同时该端中性母线接地刀闸又闭合时,则可能会有大电流流过站内接地网,造成地网损坏。为避免这种情况的发生,也配备有专门的保护。 对于双极直流输电系统,直流开关场内的大部分故障是由于单极设备的原因引起,只对单极的运行产生影响。但在直流开关场的中性线侧,有一段双极共用的中性母线,发生在该处的对地短路故障或开路故障,将直接影响双极的运行,甚至导致双极停运.直流控制保护系统通常双重化配置,如果双通道的故障切换逻辑失灵,将导致因控制系统全部失去而使直流系统停运。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条