1) sprinkler hydrostatic pressure-tight test

喷头耐压试验
2) sprinkler durability test

喷头耐久试验
3) pressure test

耐压试验
1.
Pressure Test of Pressure Vessel in Refrigeration Equipment;

制冷装置中压力容器的耐压试验
2.
Discussion on pressure test methods for vertical vessels;

直立容器耐压试验方法探讨
3.
Pressure test in periodical examination of pressure vessel;

压力容器定期检验中的耐压试验
4) withstanding voltage test

耐压试验
1.
A preventive withstanding voltage test of cable was made for guaranteeing the power supply for an important international meeting.
通过对某10kV电缆进行预防性耐压试验,发现电缆的绝缘存在缺陷。
2.
This paper sets forth the disadvantages of DC withstanding voltage test of cross-linked power cable,the method of AC withstanding voltage test(focused on the principle and advantage of series resonant withstanding voltage test method),the standard of AC withstanding voltage test,the application and caution of resonant power products.
通过列举交联电缆直流耐压试验的缺点、电缆交流耐压试验方法(重点以串联谐振耐压试验的基本原理、方法、优点为例)、介绍交流耐压试验标准、谐振电源产品应用实例和使用注意事项,对电力电缆的耐压试验方法做了些许浅显论述,探讨了变频谐振方法在交联电缆现场交流耐压中的效果和可行性。
5) withstand voltage test

耐压试验
1.
Study on feasibility using resonance device to do AC withstand voltage test of large-capacity machine;
论使用谐振装置对大电机交流耐压试验的可行性
2.
The paper summarizes DC withstand voltage test,ultra-low frequency withstand voltage test,oscillation wave voltage test and variable frequency vibration test.
概述了XLPE电缆的直流耐压试验、超低频耐压试验、振荡波电压试验和变频谐振试验,提出了直流耐压试验存在的问题,对运行过的电缆不再推荐做直流耐压试验,指出了超低频0。
3.
The current withstand voltage test methods to XLPE power cable in detail was summarized.

对XLPE交联聚乙烯电力电缆的耐压试验方法作了总结,并根据宝钢电力电缆安装后现场试验的做法和问题,结合国内外现行的不同标准,论述了变频谐振试验在宝钢交联电力电缆的应用效果,给出了进一步研究的建议。
6) voltage withstand test

耐压试验
1.
Analysis on using variable-frequency series-resonant voltage withstand test;

浅析变频串联谐振耐压试验的应用
2.
It is verified that the BPD frequency conversion power definitely can be used not only in resonance voltage withstand test of large capacity equipment for example electric cables and GIS,but also in partial discharge test of transformer.
介绍了某供电公司对主变局放和谐振耐压试验电源的研究和选用思路,简要介绍了局放和耐压试验现场实施情况,证实了BPD型变频电源不仅可以用于GIS及电缆等大容量设备的谐振耐压试验,而且可以用于变压器的局部放电试验。
3.
This paper expatiates on the different methods and contents of acceptance and preventive tests of 6~10 kV and 35 kV XLPE cables, indicating the defects in conventional DC voltage withstand test and recommending variable~frequency series~resonant test for the acceptance and preventive tests of XLPE cables.
并指出传统的直流耐压试验存在不足之处,对交联聚乙烯绝缘电缆的交接和预防性试验应优先采用变频率串联谐振试验。
补充资料:喷头
喷头
sprinkler head
pentou喷头(sprinkler head)将具有一定压力的水喷到空中,形成细小水滴进行喷洒的一种设备。也称喷洒器。按照喷洒特点,喷头可分为散水式和射流式两大类。以水膜形式向外喷洒的称为散水式喷头;以集中射流形式向外旋转喷洒的称为射流式喷头。 最早的散水式喷头为一端封闭的短管,封闭端侧面有槽缝,.压力水经槽缝喷出时形成水膜。早期的射流式喷头即喷壶上的莲蓬头,压力水自小孔喷出时形成细小射流。现代的喷头出现于20世纪初,开始是散水式喷头或喷洒孔管及喷嘴管,随后又制成了旋转的射流式喷头。第二次世界大战后,出现了性能甚好的摇臂式喷头,并广泛使用在农业喷灌上。80年代初,中国又研制成功了用射流元件控制的旋转式喷头。 散水式喷头以形成水膜的方式分类,喷出的水冲击折射锥(板)形成水膜者称折射式喷头;水喷出时依不同形状的缝隙形成水膜的称缝隙式喷头,水旋转喷出形成水膜的称离心式喷头。散水式喷头所需的工作水头较低,一般为15一30米,雾化较好,且结构简单、工作可靠、价格便宜。但其作定位喷洒时控制面积小,喷灌强度高,因此除用于苗圃、绿地、公园等场合外,多安装在时针、平移等大型喷灌机上作行走喷洒。 射流式喷头多系单股或双股射流,用旋转喷体的方法喷洒。射流式喷头的构造比较复杂,其主要组成部分为旋转密封机构、流道和驱动机构。对于可双向旋转的喷头,还装有换向机构。此外,有的喷头还装有水流粉碎针等附件。射流式喷头依驱动喷体旋转方式分为反作用式、摇臂式和叶轮式三种: 反作用式喷头是靠驱动机构使射流偏转,使水流对旋转轴产生反作用力矩,驱动喷头旋转。简单的反作用式喷头是在喷嘴上另打斜孔,或在嘴外设置挡片,使射流转向而产生反作用力矩。这种喷头多为双嘴,主喷嘴仍直射以取得较远的射程。由于喷头起动之后越转越快,要到驱动力矩平衡了摩擦力矩,转速才能稳定,因此转速快,射程仍然受到影响,这种喷头只用于小流量的场合,其工作水头一般为20一30米,喷水量为0.2一2米“/小时,射程5一巧米。大型的反作用式喷头有多种形式,其中常用的是垂直摇臂式喷头,它的驱动机构是一个绕水平轴摆动的摇臂,利用射流的冲力和摇臂上的平衡重,使摇臂前端的折射板间歇进入射流,迫使水流转向,从而获得间歇反作用力矩,使喷体稳定步进旋转。这种喷头的工作水头为40一80米,射程30一70米,喷水量为15一150米”/小时。由于水量大,射程远,所以有些国家也把它称为雨炮。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。