Nowadays using high quality PCB Rogowski coils electronic current transformer in the protection of power system is a trend along with the increase of capacity,heighten of voltages and automation of modern power system.
本文研究了PCB空心线圈电流互感器输出对短路电流的非周期性分量的影响,发现其取决于积分器的上限截止频率ωT,并通过实验给出了具有优异工频暂态性能的PCB空心线圈电流互感器中T型积分器的最佳匹配时间常数。
2) PCB current transformer
PCB电流互感器
1.
The structure principle and characteristics of PCB current transformer are analyzed.
提出了一种以PCB电流互感器为基础的新型微机线路保护装置的设计方案,分析了PCB电流互感器的结构原理及特点,在此基础上设计了数据采集接口,整套系统采用双CPU结构,同时配合CPLD实现接口电路的扩展、时序控制以及地址译码。
3) PCB air-core coil
PCB空心线圈
1.
Current-voltage converter based on PCB air-core coil
PCB空心线圈电流变换器研制
4) air core current transformer
空心电流互感器
1.
Optically powered air core current transformer applied in circuit breaker is reported in several aspects including the theory,the structure and the properties.
介绍了一种应用于断路器中的光供电式空心电流互感器的原理、结构及性能。
6) printed circuit board air core coil
PCB空芯线圈
补充资料:PC
聚碳酸酯(双酚A型)化学名称2,2-双(4-羟基苯基)丙烷聚碳酸酯,是由酯交换法和光气化法制得。平均分子量3.57×104。无定形透明颗粒.无味、天臭、无毒。相对密度1.20-1.43。没有明显熔点,220-230℃呈熔融状态。透光率高,吸水性低,耐冲击,韧性好.蠕变小,制品尺寸稳定。耐热性和耐寒性较好.玻璃化温度149-150℃.热变形温度135℃(1.82MPa)、分解温度>310 ℃,脆性温度-l00 ℃,使用温度-100~120 ℃。耐稀酸、耐油、不耐碱。溶于二氯甲烷、二氯乙烷、氯仿、三氯乙烯、四氯乙烷、四氢呋喃、三甲酚、磷酸三甲酯等。疲劳强度较低,容易产生应力开裂。具有优良的高温电性能,具有耐燃自熄性。拉伸强度 >60MPa, 伸长率>60%,弯曲强度>95MPa。