1) transient voltage quality
暂态电压质量
1.
Voltage quality problem is typically one of power quality problems,and currently the pricing of transient voltage quality service is a serious problem in power market.
综合考虑了用户和系统的利益,重点讨论暂态电压质量问题,主要针对电压暂降产生时的4项重要因素:电压暂降幅值、持续时间、(某时段内)负荷、单次暂降造成的经济损失等,提出了一套暂态电压质量服务的综合定价策略。
2) transient power quality
暂态电能质量
1.
Monitoring and analysis of transient power quality for Hangzhou economic and technological development zone;
杭州经济技术开发区暂态电能质量的监测与分析
2.
Auto recognition of transient power quality disturbances based on wavelet and neural network;
基于小波变换和神经网络的暂态电能质量扰动自动识别
3.
Custom power technology and improvement of transient power quality;
用户电力技术与暂态电能质量的改善
3) transient voltage
暂态电压
1.
Research on a fault phase selection algorithm based on fault transient voltage;
基于故障暂态电压的故障选相算法的研究
2.
The traditional simulating calculation of transient voltage distribution in the power transformer windings is a subject about which many papers have been written,but results of them need program.
传统对电力变压器绕组中暂态电压分布的仿真计算有多种,但均需编程计算而得,为此提出了一种适用于PSpice仿真的电力变压器绕组中暂态电压分布的电路模型,并对该变压器雷电过电压时的暂态电压分布及正常运行电压分布进行了仿真,结果表明该模型可表达绕组暂态时的表现,且大大简化了计算过程。
3.
The system has the character of simple structure,excellent performanee and stability,and can be used for the measurement of different transient voltage in power system.
作者研究了一种采用电容式探头直接测量带电体表面电场强度以实现电压测量的测量系统,该系统的特点是结构简单、测量性能优良、稳定性好,可用于电力系统各种暂态电压的测量。
4) index of transient power quality
暂态电能质量指标
5) dynamic power quality problem
暂态电能质量问题
6) transient over-voltage
暂态过电压
1.
For the large generator stricken by the operational over-voltage in power stations,a field-circuit analysis method of transient over-voltage is presented to study the transient over-voltage field-circuit model of large generator.
针对在厂站操作过电压冲击下的大型发电机,建立一种暂态过电压的场路分析方法,研究大型发电机的暂态过电压场路分析模型。
2.
Based on that,the power system of Yangtze River Delta region was used as an equivalent typical multi-infeed HVDC model,and the traditional SCR/ESCR,multi-infeed SCR/ESCR,the multi-infeed interaction factor,and the transient over-voltage were calculated.
对长三角多馈入直流输电系统进行等值,计算了各直流系统的传统短路比/有效短路比、多馈入短路比/有效短路比、多馈入相互作用因子,以及工频暂态过电压,并对淮南—上海特高压交流线路投产的影响进行了敏感性分析。
补充资料:电能质量
电能质量
electric power quality
d lorlrleng Zh一110,〕g电能质t(eleetriC power quality)衡量电力系统对用户供应电力的频率、电压、波形是否符合规范条件。 在一个理想的交流电力系统中,电能是以一恒定的工业频率(50Hz或60Hz)和正弦的波形,按规定的电压水平向用户供电。在三相交流电力系统中各相电压和电流应该是幅值相等,相位相差120。的对称状态。电能质量一般用频率、电压、波形和三相电压、电流的不平衡度来衡量。 电力系统中各种发、输、配电设备和用电设备一般都是按额定工业频率和各种电压等级的额定电压来设计的,在这种电能质量的条件下.电气设备的运行性能是最佳的,效率是最高的。任何频率和电压对额定值的偏差都将影响这些设备的运行性能和效率.以及由这些设备所生产的产品质量和数量,同时也会缩短各种设备的寿命。所以,各国和各电力系统为r保证电气设备的正常运行.都规定了相应的频率和电压质量标准(见电力系统频率和电压质量)。 理想的电压波形是正弦形的.但是由于各种1卜线性负荷的接人.使电压和电流波形发生畸变.出现各次谐波。在三相交流电力系统中.大容量单相负荷的出现,单相负荷在三相系统中分布的不均匀性.单相负荷投人和断开的随机性,以及电力系统各相元件阻抗的不等,都会使对称的三相系统中出现负序和零序的电压和电流分量。电力系统中的谐波和负序、零序分量都将影响各种电力设备和通信线路的正常运行性能,所以各国及各电力系统也都拟订了管理电力系统谐波的规定和电力系统不平衡度的标准(见波形质1及电压和电流不平衡度)。 此外,电压波动和闪变、电压跌落(见电压质1)等也都是表征电能质量的指标。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条