说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 水消防设计
1)  water fire fighting design
水消防设计
1.
Aiming at some problems occurred in water fire fighting design of Citic urban era,the design and related calculation of indoor water supply system for hydrant in,the automatic fire extinguishing sprinkle system and large space intelligent active sprinkle system were illustrated so as to guarantee the fire fighting design of complex building more economic and proper.
针对在中信城市时代水消防设计中遇到的一些问题,就室内消火栓给水系统、自动喷水灭火系统、大空间智能型主动喷水灭火系统的设计及相关计算作了阐述,以确保该类综合楼的消防设计更加经济合理。
2)  water supply design for fire control
消防给水设计
1.
Discussion on water supply design for fire control of commercial building;
谈商业建筑的消防给水设计
3)  fire design
消防设计
1.
The fire design of underground civil defense project;
浅谈地下人防工程的消防设计
2.
Behavior of fire in underground civil defense work and the points needing attention during fire design and installation;
地下人防工程火灾特点与消防设计施工
3.
Drainage and fire design experience of one international shopping center
某国际购物中心给排水及消防设计体会
4)  fire protection design
消防设计
1.
The fire protection design of buik tubular polypropylene plant;
本体环管法聚丙烯装置的消防设计
2.
Discussion on the fire protection design of city road tunnel;
城市地下公路隧道工程消防设计探讨
3.
Application of resk assessment to the fire protection design of atrium;
风险评估在建筑中庭消防设计中的应用
5)  Fire fighting design
消防设计
1.
Combined with fire protection code in architecture design and actual situation of Yangquan city the matters needing attention in fire fighting design in multistory buildings are discussed according to the distribution of fire cock, pump adapter in high pressure system and other aspects.
结合建筑设计防火规范和阳泉市实际情况 ,探讨了多层住宅的消火栓布置 ,底商住宅的定性问题 ,常高压系统水泵接合器的设置等几个消防设计中值得关注的问题 ,使设计人员更透彻地理解规范 ,设计出更实用的消防设计方
2.
Since there is no fire fighting specification for the liquid ammonia spherical tank,fire fighting design for a 400 m 3 ammonia tank of one compound fertilizer factory is done,with reference to the fire fighting sp.
在现行规范尚无如何对液氨球罐进行消防的情况下 ,参考地上立式储罐的消防规定 ,对某复合肥厂一座 40 0m3 液氨球罐所做的消防设计是一种可行的尝试 ,同时也说明应尽快对液氨球罐的消防设计作出明确规
3.
In electrical fire fighting design for linen mill,it is necessary to confirm the design to the requirements of standards along with the progress of science and technology and improvement of national fire fighting standards.
在亚麻企业电气消防设计中 ,需要随着科技进步以及国家消防规范的逐步完善 ,使设计符合规范之要求。
6)  fire control design
消防设计
1.
Study on fire control design measures for high-rise buildings;
高层建筑消防设计措施探究
补充资料:安全给水设施设计


安全给水设施设计
design of emergency water supply facilities

anquan Jishu一sheshl sheji安全给水设施设计(design of emergeneywater supply faeilities)对于中断给水会使冶金炉等需要冷却的设备烧坏,甚至出现重大事故的安全用水户,所采取的专门给水设施的设计。 安全用水户主要有:炼铁高炉炉体和热风炉热风阀,炼钢平炉炉头水套及烟道变向阀,电沪电极及炉盖,钢包精炼炉炉盖及电极、钢水真空处理机械间接冷却,连铸机结晶器,设备间接冷却、二冷区喷琳装置,轧钢加热沪、退火炉,铁合金电炉、真空炉和有色冶金闪速炉等的水冷构件。 安全给水措施及要求(l)给水泵站要设两路独立电源,并能自动倒换。对安全给水专用泵需配备第三路电源—保安电源。例如,从第三个电源点接入电源,或设置柴油发电机组;当不设置保安电源时,可设置柴油机传动的专用泵,在发生停电事故时保安电源熊自动投入或柴油机能自动快速启动专用泵(一般10一305内),保证连续给水。(2)设置安全给水专用水塔(水箱)。水塔的有效容积,要满足电源转换或柴油机备用泵启动前的安全用水量要求,一般按给水范围内各安全用水户10一3omin平均总用水量确定;水塔高度需满足设备安全用水的压力要求。当工厂附近有条件建高位水池时,可结合全厂性的安全给水统一考虑,其容积一般按全厂安全给水范围内的各用户2~3h平均总用水量确定,用专用管道接至各安全用水户。(3)给水泵站通常设计成地下自灌启动式,配备一定数量的备用泵。(4)采用双管或环状管网供水。 安全给水系统,一般均配备完整、可靠的自动控制、计量检测和报警装置等自控仪表设备,以便在发生事故时迅速处理。 设备及构筑物主要设备有给水泵、供配电装置、柴油发电机组、柴油机备用泵、自动切换阀、事故报警装置等。两路或第三路电源应能自动转换,保安电源或柴油机传动的备用泵需按事故时的安全给水量和水压选择,发生停电事故时,能迅速自动启动。构筑物有供水泵房、水塔或高位水池以及管网等。 (涂硕受肖植南)
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条